LMR Series

Low Loss Group: RG8/U & Larger Sizes:CXP1318FX, Heliax (Hard-Line), & LMR type Series.

   

COAX CABLES (50 OHM) LOW LOSS GROUP
Note:CXP1318FX, LMR-400, LMR-400-UF are the same physical size as RG8/U


Updated: June/27/2014 19:22 (UTC/GMT)

CXP1318FX (RG8/U Size)
Double Shld, Flexible, Low Loss, UV/DB Jkt
Like LMR-400-UF, Belden 9913F

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

 

Low Loss
High-Flexibility 10 (19X23) Bare Copper

(2) 100% Bonded Alum Foil
+95% Tinned Copper
Gas-Injected Foam Polyethylene

Black Non-Contaminating Ultra-Violet Resistant Direct Burial
0.405
-40°c to +85°c

84%
24.5pF/ft

10...0.5
30...0.8
50...1.1
150...1.9
220...2.3
450...3.3

1, 5, 6, 7, 9, 11, 14, & 15

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

 

Price 100-499ft

Price 500-999ft

Price 1000ft

Enter quantity in feet

Cable Features: Double Shld, Low Loss, Very Flexible, UV Res/DB Jkt. Use for directional (rotor) antennas and crankup towers.
Ready Made Assemblies


1.25ft

1.15ft

.95ft

LMR400UF

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

Flexible Low Loss
10 (7 X 19) Bare Copper

(2) 100% Bonded Alum Foil
+90% Tinned Copper
Foam Polyethylene

Black Thermoplastic Elastomer
.405
-40°c to +85°c

85%
24pF/ft

10...0.5
30...0.8
50...1.1
150...1.9
220...2.3
450...3.3

1, 5, 6, 7, 9, 11, 14, & 15

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

Price 100 & Greater

Enter quantity in feet

Cable Features: Double Shld, Low Loss, Remains flexible in extreme cold, and good for directional antennas.


1.54FT

ANDREW® CNT400
Like LMR-400

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

Low Loss
10 (solid) BCCAL

(2) 100% Bonded Alum Foil
+90% Tinned Copper
Foam Polyethylene

Black Polyethylene
0.405
-40°c to +85°c

85%
24pF/ft

10...0.4
30...0.7
50...0.9
150...1.5
220...1.9
450...2.7
900...3.9
1200...4.5
2400...6.6

1, 5, 6, 7, 9, 11, 14, & 15

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

Price 100-499ft

Price 500-999ft

Price 1000

Enter quantity in feet

Cable Features: Double Shld, Low Loss, Weatherproof Jacket and perfect for stationary antennas.
Ready Made Assemblies


.105ft

.99ft

.90ft

ANDREW® CNT600
Like LMR-600

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

1/2 inch Low Loss 0.176 inch (solid) BCCAL

(2) 100% Bonded Alum Foil
+90% Tinned Copper
Foam Polyethylene

Black Polyethylene
0.590
-40°c to +85°c

87%
23.4pF/ft

150...1.0
220...1.2
450...1.7
900...2.5
1200...2.9
2400...4.3
5800...7.3

1, 5, 6, 11, & 14

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

Price 100 & Greater

Enter quantity in feet

Cable Features: Double Shld, VERY Low Loss, Weatherproof Jacket and perfect for stationary antennas.
Ready Made Assemblies


1.79ft

LMR600UF

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

1/2 inch Flexible Low Loss 0.177 inch (stranded) Bare Copper

(2) 100% Bonded Alum Foil
+90% Tinned Copper Foam
Polyethylne

Black Thermoplastic Elastomer
0.590
-40°c to +85°c

87%
23.4pF/ft

150...1.2
220...1.4
450...2.1
900...3.0
1200...3.5
2400...5.1

1, 5, 6, 11, & 14

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

 

Price 100 & Greater

Enter quantity in feet


2.59FT

ANDREW® CNT600DB
Like LMR-600-DB

RG Type, Description, AWG (Stranding)

(No.) of Shields
% of Coverage
Dielectric

Jacket Type
O.D.
Temp Rating

Nom. Vel of Prop.
Nom Cap. pF/ft

Nom. Attenuation
Frequency in Mhz
db/100ft

Connector Types
Connector Key

Technical Note:

1/2 inch
Low Loss
0.176 inch (solid) BCCAL

(2) 100% Bonded Alum Foil
+90%Tinned Copper
Foam Polyethylene w/Flooding Compound

Black Polyethylene
0.590
-40°c to +85°c

87%
23.4pF/ft

150...1.0
220...1.2
450...1.7
900...2.5
1200...2.9
2400...4.3

1, 5, 6, 11, & 14

Actual measured values may vary somewhat from the calculated numbers based on manufacturing tolerances, cable length, connectors, operating frequency, and measurement accuracy.

500ft Minimum

Enter quantity in feet


1.89FT

Andrew Heliax® Assemblies
Updated: June/27/2014 19:22 (UTC/GMT)

CONNECTOR KEY

* 1: UHF PL259 MALE, 2: UHF PL259 FEMALE, 3: UHF or "N" MALE w/UG175 Reducer, 4: UHF or "N" MALE w/UG176 Reducer, 5: "N" MALE, 6: "N" FEMALE, 7: BNC MALE, 8: BNC FEMALE, 9: SMA MALE, 10: SMA FEMALE, 11: TNC MALE, 12: TNC FEMALE, 13: "F" MALE, 14: 7/16" DIN, 15: MINI UHF MALE, 16: SMA Reverse Polority.
Although a connector is listed herein, it may not necessarily be stocked. Therefore, a minimum purchase may apply.
Updated: June/27/2014 19:22 (UTC/GMT)
All information in this catalog is presented as a guide in product selection and is believed to reliable. Errors are subject correction in subsequent updates. Although CABLE X-PERTS, INC has taken precautions to ensure accuracy of the product information, the specifications of products contained herein are subject to change without notice.